141 research outputs found

    Management of peri-prosthetic fractures around total hip arthroplasty: a contemporary review of surgical options

    Get PDF
    The burden of periprosthetic fractures is increasing with increasing volumes of total hip arthroplasty. These injuries often occur in older patients with more significant co-morbidity and osteopenia. Management of these injuries is often resource intensive and can present significant socioeconomic challenges. Understanding the principles of surgical management these cases and recognising when fixation or replacement is required is critical. The aim of this article is to present a contemporary evidence-based review of the surgical fixation options for management of periprosthetic fractures in the presence of well-fixed or loose components

    Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements

    Get PDF
    PURPOSE: Ceramic coatings have been used in metal-on-polyethylene (MOP) hips to reduce the risk of wear and also infection; the clinical efficacy of this remains unclear. This retrieval study sought to better understand the performance of coated bearing surfaces. METHODS: Forty-three coated MOP components were analysed post-retrieval for evidence of coating loss and gross polyethylene wear. Coating loss was graded using a visual semi-quantitative protocol. Evidence of gross polyethylene wear was determined by radiographic analysis and visual inspection of the retrieved implants. RESULTS: All components with gross polyethylene wear (n = 10) were revised due to a malfunctioning acetabular component; 35 % (n = 15) of implants exhibited visible coating loss and the incidence of polyethylene wear in samples with coating loss was 54 %, significantly (p = 0.02) elevated compared to samples with intact coatings (14 %). CONCLUSIONS: In this study we found evidence of coating loss on metal femoral heads which was associated with increased wear of the corresponding polyethylene acetabular cups

    Clinically insignificant trunnionosis in large-diameter metal-on-polyethylene total hip arthroplasty.

    Get PDF
    OBJECTIVES: Mechanical wear and corrosion at the head-stem junction of total hip arthroplasties (THAs) (trunnionosis) have been implicated in their early revision, most commonly in metal-on-metal (MOM) hips. We can isolate the role of the head-stem junction as the predominant source of metal release by investigating non-MOM hips; this can help to identify clinically significant volumes of material loss and corrosion from these surfaces. METHODS: In this study we examined a series of 94 retrieved metal-on-polyethylene (MOP) hips for evidence of corrosion and material loss at the taper junction using a well published visual grading method and an established roundness-measuring machine protocol. Hips were retrieved from 74 male and 20 female patients with a median age of 57 years (30 to 76) and a median time to revision of 215 months (2 to 324). The reasons for revision were loosening of both the acetabular component and the stem (n = 29), loosening of the acetabular component (n = 58) and infection (n = 7). No adverse tissue reactions were reported by the revision surgeons. RESULTS: Evidence of corrosion was observed in 55% of hips. The median Goldberg taper corrosion score was 2 (1 to 4) and the annual rate of material loss at the taper was 0.084 mm(3)/year (0 to 0.239). The median trunnion corrosion score was 1 (1 to 3). CONCLUSIONS: We have reported a level of trunnionosis for MOP hips with large-diameter heads that were revised for reasons other than trunnionosis, and therefore may be clinically insignificant.Cite this article: H. S. Hothi, D. Kendoff, C. Lausmann, J. Henckel, T. Gehrke, J. Skinner, A. Hart. Clinically insignificant trunnionosis in large-diameter metal-on-polyethylene total hip arthroplasty. Bone Joint Res 2017;6:52-56. DOI: 10.1302/2046-3758.61.BJR-2016-0150.R2

    International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty in the same way? An analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH)

    Get PDF
    AIMS: There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. METHODS: Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods. RESULTS: Overall agreement between the orthopaedic centres and the recommended treatment plans for the ten patients with MOM hip implants was moderate (kappa = 0.6). Full agreement was seen in a third of cases, however split decisions were also seen in a third of cases. Units differed in their interpretation of the significance of the investigation findings and put varying emphasis on serial changes, in the presence of symptoms. DISCUSSION: In conclusion, the management of raised or rising blood metal ions, cystic pseudotumours and peri-acetabular osteolysis led to inconsistency in the agreement between centres. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision making. TAKE HOME MESSAGE: A lack of evidence and the subsequent variation in regulator guidance leads to differences in opinions, the clinical impact of which can be reduced through a multi-disciplinary team approach to managing patients with MOM hip implants. Cite this article: Bone Joint J 2016;98-B:179-86

    Importance of Preoperative Imaging in Acetabular Revision Surgery - A Case Report

    Get PDF
    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures

    ПАТОЛОГИЯ, ВЫЗВАННАЯ ИМПЛАНТАТОМ: АЛГОРИТМ ОПРЕДЕЛЕНИЯ ЧАСТИЦ ПРИ ГИСТОПАТОЛОГИЧЕСКОМ ИССЛЕДОВАНИИ СИНОВИАЛЬНО-ПОДОБНОЙ ОКОЛОПРОТЕЗНОЙ мембраны (SLIM)

    Get PDF
    In histopathologic SLIM diagnostic (synovial-like interface membrane, SLIM) apart from diagnosing periprosthetic infection particle identification has an important role to play. The differences in particle pathogenesis and variability of materials in endoprosthetics explain the particle heterogeneity that hampers the diagnostic identification of particles. For this reason, a histopathological particle algorithm has been developed. With minimal methodical complexity this histopathological particle algorithm offers a guide to prosthesis material-particle identification. Light microscopic-morphological as well as enzyme-histochemical characteristics and polarization-optical proporties have set and particles are defined by size (microparticles, macroparticles and supra- macroparticles) and definitely characterized in accordance with a dichotomous principle. Based on these criteria, identification and validation of the particles was carried out in 120 joint endoprosthesis pathological cases. A histopathological particle score (HPS) is proposed that summarizes the most important information for the orthopedist, material scientist and histopathologist concerning particle identification in the SLIM.Важную роль при гистопатологическом исследовании синовиально-подобной околопротезной мембраны (SLIM), наряду с диагностикой околопротезной инфекции, играет идентификация частиц. Различия в патогенезе частиц и разнообразии материалов для эндопротезирования объясняют ту гетерогенность, которая затрудняет диагностическую идентификацию частиц. По этой причине был разработан гистопатологический алгоритм диагностики частиц, который при минимальных методологических сложностях обеспечивает идентификацию частиц материала протеза. Простые микроскопически-морфологические и энзим-гистохимические характеристики, а также поляризационно-оптические свойства позволяют определить размер частиц (микрочастицы, макрочастицы и супер-макрочастицы) и характеризовать их по дихотомическому принципу. На основании этих критериев были выполнены идентификация и аттестация частиц в 120 случаях патологической реакции на эндопротез сустава. Предложена гистопатологическая шкала частиц (HPS), которая суммирует важнейшую информацию для ортопедов, материаловедов и гистопатологов, касающуюся идентификации частиц методом SLIM

    Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure.</p> <p>Methods</p> <p>The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.</p> <p>Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests.</p> <p>Results</p> <p>A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (<it>p </it>< 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (<it>p </it>= 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (<it>p </it>= 0.018).</p> <p>Conclusions</p> <p>In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.</p

    Oral Thromboprophylaxis Following Total Hip or Knee Replacement: Review and Multicentre Experience with Dabigatran Etexilate

    Get PDF
    The risk of venous thromboembolism (VTE) in patients undergoing total knee or hip replacement surgery is high. As a result, thromboprophylaxis is highly recommended. While current thromboprophylactic agents, such as low molecular weight heparins (LMWH) and vitamin K antagonists, are safe and effective their use can be problematic. Therefore, there is a need for alternative anticoagulants that are as safe and effective as conventional agents, but are more convenient and easier to use. Dabigatran etexilate, a direct thrombin inhibitor, is one such anticoagulant. For VTE prevention following major orthopaedic surgery, dabigatran etexilate shows similar efficacy and safety to the LMWH enoxaparin, and is approved for use in more than 75 countries, including Europe and Canada. Here, we summarize and discuss the experiences of four German clinics that have recently introduced dabigatran etexilate into clinical practice. Overall, dabigatran etexilate was well received by patients, surgeons and nurses, and compared favourably with enoxaparin. Staff appreciated the oral, single-dose administration of dabigatran etexilate. Patient satisfaction was high, especially in those individuals who had previously used LMWHs. In this review, we also address a number of questions that were asked by patients or staff; this will be of relevance to orthopaedic surgeons and nurses. We conclude that, in these four German clinics, dabigatran etexilate offered an effective oral alternative to existing thromboprophylactic agents in patients undergoing major orthopaedic surgery

    10-Jahres-Ergebnisse eines nichtzementierten modularen Revisions-Schaftes in der Hüftprothetik

    No full text
    corecore